WOODWARD 8200-1300 Digital Steam Turbine Controller
➤ Model: 8200-1300
➤ Stock: 1-3pcs (IN STOCK)
➤ Shelf life: 12 months
➤ Product Status: Original Genuine
➤ supply: available from HONG KONG SAUL ELECTRICAL LIMITED

WOODWARD 8200-1300 Digital Steam Turbine Controller
The WOODWARD 8200-1300 belongs to the Peak 150 digital steam turbine controller series, alongside the 8200-1312 you previously inquired about. It is the model within this series designed for low-voltage DC power supply environments and is recognized in the industrial sector as a reliable speed control solution.
1. Product Overview
The Woodward 8200-1300 is a digital regulator specifically designed for single-valve or single-actuator steam turbines. It integrates speed monitoring, process control, and equipment protection functions into a single unit.
The primary difference between this model and the 1312 model lies in the input power supply:
8200-1300: Designed for 24V DC (18–40V DC) power supply systems.
8200-1312: Designed for 120V AC/DC high-voltage power supply systems.

2. Key Features and Technical Specifications
High-Precision Speed Control: Utilizes a 16-bit microprocessor to deliver exceptional speed control accuracy and dynamic response.
Dual Dynamic Parameter Settings: Enables configuration of two independent PID parameter sets for different turbine operating phases (e.g., cold start and loaded operation).
Critical Speed Avoidance: Supports up to three configurable critical speed avoidance bands to prevent prolonged turbine operation at resonance frequencies, safeguarding mechanical structures.
Flexible Input/Output:
Redundant Speed Input: Supports dual MPU (magnetoelectric sensor) inputs with automatic switching upon loss of primary signal.
Cascade Control: Accepts external 4-20mA signals (e.g., inlet pressure, exhaust pressure, compressor flow) as auxiliary control loops.
Robust Industrial Protection: Modular design with NEMA 4X-rated front panel for superior vibration resistance.
Application Scenarios
Due to its 24V DC power supply characteristic, the 8200-1300 is commonly used in industrial sites with DC backup battery banks:
Backup Pump Drive: For emergency feedwater pumps or lubricating oil pumps driving turbines in petrochemical plants.
Small-Scale Cogeneration: Used in small to medium-sized factories to regulate backpressure turbines, maintaining constant production steam pressure.
Compressor Stations: Drives centrifugal compressors, automatically adjusting speed according to process requirements.
Harsh Environment Retrofits: Serves as a modern electronic replacement for outdated mechanical speed controllers